Please use this identifier to cite or link to this item:
http://repositorio.yachaytech.edu.ec/handle/123456789/574
Title: | Electrical characterization of flexible ECG patch |
Authors: | Almeida Galárraga, Diego Alfonso Milán Cucurí, Nataly Sabina |
Keywords: | Electrodos secos Electrocardiograma Impedancia de la piel Impresión 3D Material conductivo Dry electrodes Skin impedance 3D printing Conductive material |
Issue Date: | Sep-2022 |
Publisher: | Universidad de Investigación de Tecnología Experimental Yachay |
Abstract: | El registro de la actividad eléctrica es fundamental para monitorear órganos como el corazón. Es de suma importancia obtener una buena calidad de señal cardíaca para el seguimiento médico y lograr un mejor diagnóstico de los problemas cardíacos. Actualmente, los electrodos húmedos o comerciales de Ag/AgCl son aceptados abiertamente en el ámbito clínico, obteniendo una buena señal cardiaca; sin embargo, presenta adversidades como abrasión, alergia e irritación de la piel, debido al gel utilizado. Por tanto, en los últimos años se ha desarrollado la investigación de electrodos secos para solventar estas adversidades y dejar de lado el uso de geles. No obstante, los electrodos secos aún presentan una impedancia mayor que los electrodos húmedos, además de ser más costosos en su producción. La impresión 3D -un método alternativo de fabricación- es más rápido y reduce costos debido al uso mínimo de recurso material. La impresión 3D abre un mundo de posibilidades para crear sensores personalizados. En esta tesis se imprimió electrodos 3D basados en un material conductivo para la medición de resistencia, impedancia de la piel y obtención de la señal cardiaca. Adicionalmente, se evaluó tanto las condiciones de impresión 3D como la preparación de la piel durante las mediciones. |
Description: | Recording electrical activity is essential to monitor organs such as the heart. It is of the utmost importance to obtain a good quality cardiac signal for medical follow-up and to achieve a better diagnosis of cardiac problems. Currently, wet or commercial Ag/AgCl electrodes are openly accepted in the clinical setting, obtaining a good cardiac signal; however, they present adversities, such as abrasion, allergy, and skin irritation, due to the gel used. Therefore, in recent years, research on dry electrodes has been developed to solve these adversities and put aside the use of gels. However, dry electrodes still have a higher impedance than wet electrodes and are more expensive to produce. 3D printing - an alternative manufacturing method - is faster and lowers costs due to the minimal use of material resources. 3D printing opens up a world of possibilities for creating custom sensors. In this thesis, 3D electrodes based on a conductive material were printed to measure resistance, skin impedance and obtain the cardiac signal. Additionally, the 3D printing conditions and the skin preparation were evaluated during the measurements. |
URI: | http://repositorio.yachaytech.edu.ec/handle/123456789/574 |
Appears in Collections: | Biomedicina |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ECBI0143.pdf | 20.96 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.